The Station settings provide the user with the ability to change the station parameters and setup for hydraulic connection, flow setting, and Cycle and Soak.
- Master Valve: Indicates which normally closed P/MV outputs the station will activate whenever it runs. Station Flow Zone assignment is required for the Flow Manager and/or Flow Monitor.
- Flow Priority (Used in Flow Manager): Check the box to prioritize a station for earlier watering in flow management.
- Flow Rate (Used in Flow Manager and Flow Monitor): Enter or learn the typical flow for the station.
- Delay: Sets the amount of time the station can run before high or low flows will cause an alarm. Set longerdelays for stations that take longer to stabilize flow.