When the ICore has the Dual Decoder installed, the system will display various messages indicating different statuses and activities. These messages can be helpful for troubleshooting.
| DUAL Module Message | Description |
|---|---|
| Ready | Normal, ready to irrigate |
| Avail Stations | Range of stations available to program to decoder addresses |
| Prog Decoder | Program a Decoder address into the decoder |
| Save | Send the address to the decoder |
| Reading… | DUAL is trying to read the decoder |
| Not Detected | Reading was unsuccessful either because there is no decoder, or decoder is bad |
| Programming… | Shown while sending the address to the decoder |
| Done | Completed successfully |
| Diagnostics | Troubleshooting tools |
| Read Current | Reads the output current in milliamps |
| Find Solenoid | Locate a solenoid (chatter function) |
| Find Stn | Enter the station number to find |
| Start | Begin chatter function |
| Stop | Stop chatter function |
| Back | Return to previous menu |
| Clear | Erase the entry to start again |
| Line Open | Two-wire path is cut or open, not connected |
| Line Fault | Two-wire path or solenoid wiring has a short circuit |
| No Communication | Cannot see I-Core facepack |
| Slot | Slot in cabinet for modular output modules- each one has a number |
| Unknown Slot Address | Module not properly inserted, pin bent or hardware malfunction |
| Running Stations | Displayed when decoder stations are active |
| Unable to Run | DUAL prevented a station from running due to high current |
| Resuming… | DUAL is about to restart the two wire path |
| ERROR | Problem programming decoders, or no decoder found in programming port. |
| Out of Range | Invalid decoder address, station number already assigned to ICM-600 module |
| Duplicate Address | Multi-station decoder has same address on both stations |
| Decoder Not Supported | Decoder type not supported by DUAL |
| Address Not set | There was a problem during the address write (check wiring) |
| Contrast… | Change screen contrast (hold Enter button for 3 seconds) |
| Capacity Exceeded | Two wire path current is above 475 mA |
| Finding Stn | Displayed during Find Solenoid function |