| Hunter Two-Wire/Decoder Comparison | ||||
|---|---|---|---|---|
![]() | ||||
| Product Name | ICD | EZ Decoder System (EZDS) | ||
| Compatible Controllers | ACC2 | HCC & ICC2 | HPC & Pro-C | |
| Max. Decoder Stations per System | 225 | 54 | 28 | |
| Wire Options | ID1 - 14 AWG | ID2 - 12 AWG | Any low-voltage, direct-burial wire will suffice | |
| Maximum Wiring Distance | 10,000' | 15,000' | EZ-1: 3,808' (12 AWG) | EZ-LR: 7,616' (12 AWG) | |
| Wire Connectors | DBRY-6 | Waterproof connections are encouraged | ||
| Two-wire Paths Available | 3 per 75 station module (9 max.) | EZDM - 2 | ||
| Decoder Station Options | 1-, 2-, 4-, 6-station (& ICD-SEN sensor decoder) | Single-station | ||
| Earth Grounding Required for Two-Wire Path | Yes | No | ||
| Hybrid Conventional/Decoder Operation | No | Yes | ||
| Programmable Sensor Decoders | Yes | No | ||
| Programmable P/MV Decoders | Yes | Yes | ||
| Handheld Programmer/Wireless Diagnostic Tool | ICD-HP | EZ-DT | ||
| Warranty | 5 years | 3 years | ||
Landscape Irrigation